The Resource Assessment of RELAP5/MOD3.2 with the LSTF experiment simulating a loss of residual heat removal event during mid-loop operation, prepared by K.W. Seul [and three others]

Assessment of RELAP5/MOD3.2 with the LSTF experiment simulating a loss of residual heat removal event during mid-loop operation, prepared by K.W. Seul [and three others]

Label
Assessment of RELAP5/MOD3.2 with the LSTF experiment simulating a loss of residual heat removal event during mid-loop operation
Title
Assessment of RELAP5/MOD3.2 with the LSTF experiment simulating a loss of residual heat removal event during mid-loop operation
Statement of responsibility
prepared by K.W. Seul [and three others]
Creator
Contributor
Author
Issuing body
Subject
Genre
Language
eng
Member of
Cataloging source
GPO
http://library.link/vocab/creatorName
Seul, K. W
Funding information
Sponsored by the Office of Nuclear Regulatory Research, U.S. Nuclear Regulatory Commission
Government publication
federal national government publication
Illustrations
illustrations
Index
no index present
Literary form
non fiction
Nature of contents
  • dictionaries
  • bibliography
  • technical reports
http://library.link/vocab/relatedWorkOrContributorName
U.S. Nuclear Regulatory Commission
Series statement
International agreement report
Series volume
NUREG/IA-0143
http://library.link/vocab/subjectName
  • Nuclear reactors
  • Nuclear reactor accidents
Type of report
Technical report.
Label
Assessment of RELAP5/MOD3.2 with the LSTF experiment simulating a loss of residual heat removal event during mid-loop operation, prepared by K.W. Seul [and three others]
Instantiates
Publication
Note
  • "Korea Institute of Nuclear Safety, Advanced Reactor Dept."
  • "August 1998."
  • "Prepared as part of the Agreement on Research Participation and Technical Exchange under the International Thermal-Hydraulic Code Assessment and Maintenance Program (CAMP)."
  • "S. Smith, NRC project manager"--Bibliographic data sheet
Bibliography note
Includes bibliographical references (page 65)
Carrier category
online resource
Carrier category code
cr
Carrier MARC source
rdacarrier
Content category
text
Content type code
txt
Content type MARC source
rdacontent
Control code
999728892
Extent
1 online resource (various pagings)
Form of item
online
Media category
computer
Media MARC source
rdamedia
Media type code
c
Other physical details
illustrations.
Specific material designation
remote
Label
Assessment of RELAP5/MOD3.2 with the LSTF experiment simulating a loss of residual heat removal event during mid-loop operation, prepared by K.W. Seul [and three others]
Publication
Note
  • "Korea Institute of Nuclear Safety, Advanced Reactor Dept."
  • "August 1998."
  • "Prepared as part of the Agreement on Research Participation and Technical Exchange under the International Thermal-Hydraulic Code Assessment and Maintenance Program (CAMP)."
  • "S. Smith, NRC project manager"--Bibliographic data sheet
Bibliography note
Includes bibliographical references (page 65)
Carrier category
online resource
Carrier category code
cr
Carrier MARC source
rdacarrier
Content category
text
Content type code
txt
Content type MARC source
rdacontent
Control code
999728892
Extent
1 online resource (various pagings)
Form of item
online
Media category
computer
Media MARC source
rdamedia
Media type code
c
Other physical details
illustrations.
Specific material designation
remote

Library Locations

  • St. Louis Mercantile LibraryBorrow it
    1 University Blvd, St. Louis, MO, 63121, US
    38.710138 -90.311107
  • Thomas Jefferson LibraryBorrow it
    1 University Blvd, St. Louis, MO, 63121, US
    38.710138 -90.311107
  • University ArchivesBorrow it
    703 Lewis Hall, Columbia, MO, 65211, US
  • University of Missouri-St. Louis Libraries DepositoryBorrow it
    2908 Lemone Blvd, Columbia, MO, 65201, US
    38.919360 -92.291620
  • University of Missouri-St. Louis Libraries DepositoryBorrow it
    2908 Lemone Blvd, Columbia, MO, 65201, US
    38.919360 -92.291620
  • Ward E Barnes Education LibraryBorrow it
    8001 Natural Bridge Rd, St. Louis, MO, 63121, US
    38.707079 -90.311355
Processing Feedback ...